Which of the following statements is TRUE for degree of disturbance of collected soil sample?
Correct answer
(A) Thinner the sampler wall, lower the degree of disturbance of collected soil sample
Solution
The degree of disturbance in a soil sample is often quantified by the area ratio (), defined as , where is the outer diameter and is the inner diameter of the sampler. A thinner sampler wall means is closer to , resulting in a lower area ratio. A lower area ratio indicates less displacement of soil during sampling and thus a lower degree of disturbance. For undisturbed samples, should ideally be less than .
Continue learning with Success Tracker
A step still unclear? Work through it with support
Use Success Tracker to ask about the reasoning, then try another GATE CE question to check your understanding.
AI-powered practice· Unlimited practice on eligible plans
- PYQs with solutions
- Attempt available previous-year questions, then compare your reasoning with the worked solution. Coverage varies by stream.
- Practice that adapts
- Choose a topic, work on weaker areas and bookmark questions to revisit. Your attempts feed your progress tracking.
- AI doubt support
- Ask follow-up questions about a step or concept while practising, instead of stopping at the final answer.
Unlimited practice is available on eligible plans. Free practice and AI usage have limits; check the current plan allowances before choosing.
This page stays readable without an account. AI responses can be wrong; check them against the solution and source material.
More questions on Subsurface Investigation
2026 Set 1 Q18The name of a person in Column 1 is to be matched with the test mentioned in Column 2. | Column 1 |…2026 Set 2 Q21Based on the Casagrande’s plasticity chart, plasticity index (in ) of inorganic clays having a…2026 Set 2 Q22Information related to foundation design is provided in table below. | Column 1 | Column 2 | | :---…2026 Set 1 Q31For a liquid, the permeability of a sandy soil having a void ratio of was determined as…2026 Set 1 Q32To obtain undisturbed clay soil sample, an Area Ratio of needs to be achieved for a…