GATE CE 2024 Set 2 — Question 49
Go beyond PYQs with Success TrackerAI-powered personalised practice and doubt support. Unlimited practice on eligible plans; AI usage limits apply.NAT+2 / -0MediumDeterminate StructuresDeterminate Structures & Energy MethodsStructural Engineering
Structural Engineering → Determinate Structures & Energy Methods → Determinate Structures
Last updated
Question
For the 6 m long horizontal cantilever beam PQR shown in the figure, Q is the mid-point. Segment PQ of the beam has flexural rigidity whereas the segment QR has infinite flexural rigidity. Segment QR is subjected to uniformly distributed, vertically downward load of 5 kN/m.
(Figure NOT to scale)The magnitude of the vertical displacement (in mm) at point Q is ________ (rounded off to 3 decimal places).

Correct answer
1.176 to 1.186
Solution
The segment QR is rigid (), so it does not bend. The load on QR acts as a concentrated force and a moment at point Q.
1.Total vertical force at Q due to UDL on QR: .
2.Moment at Q due to UDL on QR: .
The vertical displacement at Q () is the deflection of the cantilever segment PQ (length ) under the action of point load and moment at its free end Q:Substituting the values:Converting to mm:Rounding off to 3 decimal places, the magnitude is .Continue learning with Success Tracker
A step still unclear? Work through it with support
Use Success Tracker to ask about the reasoning, then try another GATE CE question to check your understanding.
AI-powered practice· Unlimited practice on eligible plans
- PYQs with solutions
- Attempt available previous-year questions, then compare your reasoning with the worked solution. Coverage varies by stream.
- Practice that adapts
- Choose a topic, work on weaker areas and bookmark questions to revisit. Your attempts feed your progress tracking.
- AI doubt support
- Ask follow-up questions about a step or concept while practising, instead of stopping at the final answer.
Unlimited practice is available on eligible plans. Free practice and AI usage have limits; check the current plan allowances before choosing.
This page stays readable without an account. AI responses can be wrong; check them against the solution and source material.
More questions on Determinate Structures & Energy Methods
2026 Set 1 Q13A thin-walled spherical gas balloon of radius and wall thickness () is subjected…2026 Set 2 Q14A rectangular singly reinforced concrete beam has a width of 300 mm and an effective depth of 550…2026 Set 1 Q14Black dot shown in the figure qualitatively represents the shear centre of the angle section. The…2026 Set 2 Q15As per IS:800-2007, design of a cantilever steel beam section for its moment capacity requires…2026 Set 1 Q15Which one of the following is utilized to determine the long-term deformation of concrete under…